УДК: 681.785.574, 53.088.3
Radiometric calibration of the IKFS-2 on-board IR Fourier spectrometer for temperature and humidity probing of the Earth’s atmosphere
Full text «Opticheskii Zhurnal»
Full text on elibrary.ru
Publication in Journal of Optical Technology
Козлов Д.А. Радиометрическая калибровка бортового инфракрасного фурье-спектрометра ИКФС-2 для температурного и влажностного зондирования атмосферы Земли // Оптический журнал. 2013. Т. 80. № 2. С. 52–58.
Kozlov D.A. Radiometric calibration of the IKFS-2 on-board IR Fourier spectrometer for temperature and humidity probing of the Earth’s atmosphere [in Russian] // Opticheskii Zhurnal. 2013. V. 80. № 2. P. 52–58.
D. A. Kozlov, "Radiometric calibration of the IKFS-2 on-board IR Fourier spectrometer for temperature and humidity probing of the Earth’s atmosphere," Journal of Optical Technology. 80(2), 110-114 (2013). https://doi.org/10.1364/JOT.80.000110
Calibrating the data of a Fourier spectrometer consists of converting the interferograms measured by the device into the spectra of the input radiation with the required radiometric and spectral accuracy. The main problems of terrestrial radiometric calibration of an on-board Fourier spectrometer are to correct the nonlinearity of the photodetector system, to determine the spectral radiance of the radiation of an on-board blackbody, and also to determine the threshold spectral brightness of the device. This article presents the results of the radiometric calibration of a flying sample of the IKFS-2 apparatus, obtained in thermovacuum tests of the device at the Keldysh Center.
Fourier spectrometer, IKFS-2, radiometric calibration, nonlinearity correction
OCIS codes: 120.6200, 300.6190, 300.6300, 300.6340
References:1. A. V. Desyatov, Yu. M. Golovin, and F. S. Zavelevich, “Calibration of the IKFS-2 on-board IR Fourier spectrometer,” Sovremennye problemy distantsionnogo zondirovaniya Zemli iz kosmosa 7, No. 2, 241 (2010).
2. F. S. Zavelevich, Yu. M. Golovin, and A. V. Desyatov, “Technological sample of IKFS-2 on-board IR Fourier spectrometer,” Sovremennye problemy distantsionnogo zondirovaniya Zemli iz kosmosa 1, 259 (2009).
3. L. Fiedler, S. Newman, and S. Bakan, “Correction of detector nonlinearity in Fourier transform spectroscopy with a low-temperature blackbody,” Appl. Opt. 4, 5532 (2005).
4. “Algorithm theoretical basis document for the Cross Track Infrared Sounder (CrIS): Sensor Data Records (SDR),” Release Date: 20.02.2009, p. 199.
5. “Dossier de définition des algorithmes IASI,” Release Date: 06.01.2011, p. 502.