УДК: 621.391.156, 535.8
Comparison of the operation of an acousto-optic spectrum analyzer and an acousto-optic pseudo-Wigner processor by analyzing the time–frequency distributions of frequency-modulated signals
Full text «Opticheskii Zhurnal»
Full text on elibrary.ru
Publication in Journal of Optical Technology
Каасик В.П., Рогов С.А. Сравнение работы акустооптических анализатора спектра и псевдо-вигнеровского процессора при анализе время-частотных распределений частотно-модулированных сигналов // Оптический журнал. 2016. Т. 83. № 5. С. 29–35.
Kaasik V.P., Rogov S.A. Comparison of the operation of an acousto-optic spectrum analyzer and an acousto-optic pseudo-Wigner processor by analyzing the time–frequency distributions of frequency-modulated signals [in Russian] // Opticheskii Zhurnal. 2016. V. 83. № 5. P. 29–35.
V. P. Kaasik and S. A. Rogov, "Comparison of the operation of an acousto-optic spectrum analyzer and an acousto-optic pseudo-Wigner processor by analyzing the time–frequency distributions of frequency-modulated signals," Journal of Optical Technology. 83(5), 290-294 (2016). https://doi.org/10.1364/JOT.83.000290
This paper compares the accuracy of the time–frequency distributions and their resolving power in the frequency–time plane of frequency-modulated radio signals when they are obtained by means of an acousto-optic spectrum analyzer and a pseudo-Wigner processor. Signals with linear frequency modulation and signals in which the frequency depends on time to a power greater than the first are considered. The results of numerical modeling are presented.
time–frequency distribution, acousto-optic spectrum analyzer, spectrogram, pseudo-Wigner distribution, close signals recognition
OCIS codes: 070.0070, 070.6120, 070.4790, 100.4550, 070.4550
References:1. L. Cohen, “Time-frequency distributions—a review,” Proc. IEEE 77(7), 941–981 (1989) [Tr. IIER 77, 72–120 (1989)].
2. V. V. Rozdobud’ko, “Broad-band acousto-optic devices for measuring the frequency and phase parameters of radio signals,” Radiotekhnika (1), 79–92 (2001).
3. V. V. Rozdobud’ko, “Analysis of the dynamic errors in acousto-optic devices for measuring the instantaneous frequencies of radar signals,” Radioélektronika (12), 3–10 (1997).
4. E. T. Aksenov, M. G. Vysotskiı˘, V. P. Kaasik, S. A. Rogov, and S. V. Rozov, “Fast-acting acoustooptoelectronic spectrum analyzer of broad-band signals,” Avtometriya (1), 78–83 (2000).
5. S. A. Rogov, E. T. Aksenov, M. G. Vysotskiy, V. P. Kaasik, and S. V. Rozov, “Acoustooptoelectronic receiver,” Proc. SPIE 4680, 248–255 (2006).
6. A. V. Anishchenko, S. A. Rogov, M. G. Vysotskiı˘, B. G. Katkov, V. A. Parfenov, S. V. Rozov, V. V. Skorokhod, V. S. Tutygin, and A. V. Yuzhakov, “Acoustooptoelectronic detector—a spectrum analyzer for measuring the parameters of radio signals in real time,” Radiotekhnika (5), 18–25 (2012).
7. J. Wilbur and F. J. Taylor, “An acoustooptic Wigner processor for time-varying signal analysis,” Proc. IEEE 75(3), 427–428 (1987) [Tr. IIER 75, 186–187 (1987)].
8. M. G. Vysotskiy, V. P. Kaasik, S. A. Rogov, and S. V. Rosov, “Experimental investigation of the optical Wigner processor,” Opt. Mem. Neural Networks (Inf. Opt.) 23(4), 271–277 (2014).
9. M. G. Vysotskiy, V. P. Kaasik, and S. A. Rogov, “Distortion in the acousto-optic Wigner processor,” Opt. Mem. Neural Networks (Inf. Opt.) 22(4), 255–260 (2013).