Study on measurement method of zero position's variation of high-precision optical sight

For Russian citation (Opticheskii Zhurnal):

Yuanyuan Zhao, Zuojiang Xiao, Huajian Li, Xiaoyi Fan, Ru Zheng Study on measurement method of zero position's variation of high-precision optical sight (Метод измерения отклонений нулевого положения марки высокоточного оптического прицела) [на англ. яз.] // Оптический журнал. 2019. Т. 86. № 5. С. 30–35. http://doi.org/10.17586/1023-5086-2019-86-05-30-35

 

Yuanyuan Zhao, Zuojiang Xiao, Huajian Li, Xiaoyi Fan, Ru Zheng Study on measurement method of zero position's variation of high-precision optical sight (Метод измерения отклонений нулевого положения марки высокоточного оптического прицела) [in English] // Opticheskii Zhurnal. 2019. V. 86. № 5. P. 30–35. http://doi.org/10.17586/1023-5086-2019-86-05-30-35

For citation (Journal of Optical Technology):

Yuanyuan Zhao, Zuojiang Xiao, Huajian Li, Xiaoyi Fan, and Ru Zheng, "Study of the measurement method of zero position variation in a high-precision optical sight," Journal of Optical Technology. 86(5), 284-288 (2019). https://doi.org/10.1364/JOT.86.000284

Abstract:

Zero position's variation is one of the important indicators to measure the stability of the optical sight. And the repeated installation's error cannot be ignored for the high-precision optical sight. So we design a device that can automatically eliminate the repeated installation's error. It consists of an automatic fitting device with a spectroscope and an autocollimator. A micro-motion fine-tuned closed-loop feedback system is formed with a pressure sensor and a piezoelectric ceramic micro-displacement device to achieve real-time adjustment of the space posture of the spectroscope. The experimental verification shows that the accuracy of system can achieve 1.5² within the 2° measurement range. Using this system, the precision of the zero position's variation of the high-precision optical sight is up to 2², which is sufficient to meet the measurement requirements for the zero position's variation of the high-precision optical sight.

Keywords:

repeated installation's error, zero position's variation, autocollimator, optical sight

OCIS codes: 260.0260, 120.0120, 080.0080

References:

1. Xu L., Jinsong W., Xuyang Z. Electronic divider reading method and its implementation of zero instrument // Acta Armamentarii. 2017. V. 38. № 12. P. 2423–2428.
2. Ying W., Jinsong W., Shibao C. Research on zero-moving detection technology for high-precision white and low-light sights // Acta Armamentarii. 2015. V. 36. № 8. P. 1481–1486.
3. Zhifu Z. Infrared sight zero calibration instrument. Jiangsu: Nanjing University of Science and Technology, 2014. 125 p.
4. Bin W., Yongliang L., Youhong Z. Research on the sighting baseline detection system of portable infrared sights // Laser and Infrared. 2010. V. 40. № 12. P. 1330–1332.
5. Feng G. Development of modern comprehensive test system for basic performance parameters of white sights. Shandong: Jinan University, 2016. 222 p.
6. Jinsong W., Zhiyong A., Hailan L. Research on measurement method of zero walking amount of infrared collimator with reflective collimator // J. Ordnance. 2010. V. 31. № 11. P. 1422–1425.
7. Yan-Feng L., Zhi-Yong A., Jin-Song W. Zero-moving detection system for infrared sights based on machine vision // Acta Optica Sinica. 2014. V. 30. № 11. P. 152–157.