DOI: 10.17586/1023-5086-2019-86-05-51-56
УДК: 617.751-072.7
Comparative analysis of the results of various visometry methods
Full text «Opticheskii Zhurnal»
Full text on elibrary.ru
Publication in Journal of Optical Technology
Коскин С.А., Волков В.В., Даниличев В.Ф., Ковальская А.А., Докторова Т.А. Сравнительный анализ результатов различных методов визометрии // Оптический журнал. 2019. Т. 86. № 5. С. 51–56. http://doi.org/10.17586/1023-5086-2019-86-05-51-56
Koskin S.A., Volkov V.V., Danilichev V.F., Kovalskaya A.A., Doktorova T.A. Comparative analysis of the results of various visometry methods [in Russian] // Opticheskii Zhurnal. 2019. V. 86. № 5. P. 51–56. http://doi.org/10.17586/1023-5086-2019-86-05-51-56
S. A. Koskin, V. V. Volkov, V. F. Danilichev, A. A. Kovalskaya, and T. A. Doktorova, "Comparative analysis of the results of various visometry methods," Journal of Optical Technology. 86(5), 301-305 (2019). https://doi.org/10.1364/JOT.86.000301
A comparison of the results of a study of visual acuity obtained using an eye chart and a chart projector at different distances with a demonstration of various optotypes was performed. It is determined that, depending on the visometry version, the results of visual acuity testing can vary significantly. For example, when using an image projector at a visual acuity range below 0.1 and a distance closer than 5.0 m, overestimation was observed. It has been established that to assess the dynamics of visual functions it is better to use the same method for studying visual acuity from a constant distance. A calculation method is proposed that allows one to obtain an exact value of visual acuity of less than 0.1 using a chart projector, provided that the distance from the screen is taken into account.
visometry, Landolt ring, eye chart, visual acuity, chart projector
OCIS codes: 170.4470
References:1. S. A. Koskin, É. V. Boı˘ko, and Yu. E. Shelepin, “The system for determining visual acuity for medical examination purposes,” Vestn. Ross. Voen.-Med. Akad. 3(19), 81–86 (2007).
2. A. H. Chen, F. N. Norazman, and N. H. Buari, “Comparison of visual acuity estimates using three different letter charts under two ambient room illuminations,” Indian J. Ophthalmol. 60(2), 101–104 (2012).
3. P. K. Kaiser, “Prospective evaluation of visual acuity assessment: a comparison of Snellen versus ETDRS charts in clinical practice,” Trans. Am. Ophthalmol. Soc. 107, 311–324 (2009).
4. J. Leinonen, E. Laakkonen, and L. Laatikainen, “Random measurement error in visual acuity measurement in clinical settings,” Acta Ophthalmol. Scand. 83(3), 328–332 (2005).
5. S. A. Koskin and V. V. Khlebnikov, “Measurement of visual acuity in clinical practice,” Oftal’mokh. Ter. 2(3–4), 40–43 (2002).
6. M. G. Balaguta, “Charts for the study of visual acuity,” Veko 7, 66–68 (2007).
7. D. A. Sivtsev, “Comparative assessment of charts for the determination of visual acuity,” Russ. Oftal’mol. Zh. 4(2), 136–158 (1925).
8. S. A. Koskin, É. V. Boı˘ko, and Yu. E. Shelepin, “Modern methods of measuring the resolving power of the visual system,” J. Opt. Technol. 75(1), 17–20 (2008) [Opt. Zh. 75(1), 22–27 (2008)].
9. M. A. Bullimore and K. Zadnik, “Consistency between visual acuity scores obtained at different test distances,” Arch. Ophthalmol. 122(11), 1729–1731 (2004).
10. “Ophtalmic optics. Visual acuity testing. Standard optotype and its presentation,” ISO 8596, 2017.
11. V. V. Volkov, A. I. Gorban’, and O. A. Dzhaliashvili, Clinical Visometry and Refractometry (Meditsina, Leningrad, 1976).
12. É. V. Boı˘ko, S. A. Koskin, N. N. Kharitonova, and M. M. Shishkin, Methods of Patient Examination in Ophthalmologic Clinics (VMedA, Saint Petersburg, 2013), p. 224.
13. A. V. Roslavtsev and A. I. Bogoslovskiı˘, On the Method of Research of Visual Acuity: Multivolume Guide to Eye Diseases (Medgiz, Moscow, 1962), Vol. 1, Book 2, pp. 137–146.