УДК: 681.786.23:685.4
Technique for obtaining digital models of sections of the human body, using the Handyscan 3D Revscan and Konica Minolta VI-910 laser 3D scanners
Full text «Opticheskii Zhurnal»
Full text on elibrary.ru
Publication in Journal of Optical Technology
Тишкин В.О., Разина Е.В. Методика получения цифровых моделей участков тела человека с использованием лазерных 3D-сканеров Handyscan 3D REVscan и Konica Minolta VI 910 // Оптический журнал. 2012. Т. 79. № 9. С. 53–59.
Tishkin V. O., Razina E. V. Technique for obtaining digital models of sections of the human body, using the Handyscan 3D Revscan and Konica Minolta VI-910 laser 3D scanners [in English] // Opticheskii Zhurnal. 2012. V. 79. № 9. P. 53–59.
V. O. Tishkin and E. V. Razina, "Technique for obtaining digital models of sections of the human body, using the Handyscan 3D Revscan and Konica Minolta VI-910 laser 3D scanners," Journal of Optical Technology. 79(9), 566-570 (2012). https://doi.org/10.1364/JOT.79.000566
This paper describes a technique for the volume scanning of sections of the human body, on the example of the arms of a man and woman, using devices of manual and stationary type. An algorithm is presented for processing the data obtained on the basis of scanning.
contactless laser 3D scanners, scan, electronic copy, hand and hand anthropometry, dimensional feature
OCIS codes: 100.6890, 230.2090
References:1. Digital hand family based on hand anthropometry, Digital Human Research Center, AIST [Electronic resource]. Address: http://www.dh.aist.go.jp/en/ research/centered/2004HandDim/.
2. T. M. Greiner, “Hand anthropometry of US Army personnel,” U.S. Army Natick Research, Development and Engineering Center, Natick: MA, No. 5, 98 (1991).
3. M. S. Rogers, A. B. Barr, B. Kasemsontitum, and D. M. Rempel, “A three-dimensional anthropometric solid model of the hand based on landmark measurements,” Ergonomics 51, 511 (2008).
4. D. Hidson, “Development of a standard anthropometric dimension set for use in computer-aided glove design,” DREO Technical Note 91–22, Defense Research Establishment OTTAWA, No. 56, 51 (1991)
5. S. W. Lee and X. Zhang, “Development and evaluation of an optimization-based model for power-grip posture prediction,” J. Biomech. 38, 1591 (2005).
6. L. Wonsup, Y. Sunghye, and Y. Heecheon, “Development of a 3D semiautomatic measurement protocol for hand anthropometric measurement,” in Proceedings of the Human Factors and Ergonomics Society 54th Annual Meeting, Vol. 54, (2008), p. 1672.
7. F. Remondino and A. Roditakis, “Human motion reconstruction and animation from video sequences,” in Proceedings of the International Conference on Computer Vision, Vol. 5, (2007), pp. 180–188.
8. F. Remondino, “3D reconstruction of static human body with a digital camera,” Proc. SPIE 5013, 38 (2003).
9. “Noncontact laser scanning,” Corporation Amethyst: 3D scanning and modelling. URL: http://www.ametist.com/3d/ (access date 7/22/2011).
10. “Handyscan 3D scanners,” Creaform: 3D scanners. URL: http://www.creaform3d.com/en/handyscan3d/products/default.aspx?v=a (access date 7/18/2011).
11. “Non-contact 3D digitizer,” Konica Minolta: 3D Measurement. URL: http://www.konicaminolta.eu/measuring-instruments/products/3d-measurement.html (access date 7/28/2011).
12. V. O. Tishkin and A. N. Vershinin, “Quality of the electronic replicas of physical objects,” Nauch. Tekh. Vest. Prikl. Info. Tekhnol. No. 52, 69 (2008).
13. V. O. Tishkin and O. V. Cherepanova, “Three-dimensional scanning and modelling,” Nauch. Tekh. Vest. Sovrem. Fiz. Trudy Mol. Uchenykh No. 37, 45 (2007).
14. V. O. Tishkin, “Technique for collecting and processing data obtained during 3D scanning,” Nauch. Tekh. Vest. SPBGUITMO No. 71, 87 (2011).
15. H. Han and Y. Nam, “The suitability of 3-dimensional body scan method in measuring body surface area,” Text. Sci. Eng. 41, No. 3, 223 (2004).
16. Z. Li, C. C. Chang, P. G. Dempsey, L. Ouyang, and J. Duan, “Validation of a three-dimensional hand-scanning and dimension-extraction method with dimension data,” Ergonomics 51, 1780 (2010).
17. X. Ju, N. Werghi, and J. P. Siebert, “Automatic segmentation of 3D human body scans,” in International Conference on Computer Graphics and Imaging, Vol. 12, (2000), p. 239.
18. C. C. Chang, Z. Li, X. Cai, and P. Dempsey, “Error control and calibration in three-dimensional anthropometric measurement of the hand by laser scanning with glass support,” Measurement 40, No. 1, 21 (2007).