ITMO
ru/ ru

ISSN: 1023-5086

ru/

ISSN: 1023-5086

Scientific and technical

Opticheskii Zhurnal

A full-text English translation of the journal is published by Optica Publishing Group under the title “Journal of Optical Technology”

Article submission Подать статью
Больше информации Back

DOI: 10.17586/1023-5086-2021-88-01-53-59

УДК: 091, 535.3

High sensitivity sensors based on open cavity in-fiber Fabry–Perot and Mach–Zehnder interferometers

For Russian citation (Opticheskii Zhurnal):

Qian Ma, Lijun Li, Fengjuan Wei, Jianhong Sun, Fei Yu, Jiahui Huang, Xingchen Gu, Yanhua Ma High sensitivity sensors based on open cavity in-fiber Fabry–Perot and Mach–Zehnder interferometers (Высокочувствительные волоконные датчики на основе встроенных интерферометров Маха–Цендера и Фабри–Перо) [на англ. яз.] // Оптический журнал. 2021. Т. 88. № 1. С. 53–59. http://doi.org/10.17586/1023-5086-2021-88-01-53-59

 

Qian Ma, Lijun Li, Fengjuan Wei, Jianhong Sun, Fei Yu, Jiahui Huang, Xingchen Gu, Yanhua Ma High sensitivity sensors based on open cavity in-fiber Fabry–Perot and Mach–Zehnder interferometers (Высокочувствительные волоконные датчики на основе встроенных интерферометров Маха–Цендера и Фабри–Перо) [in English] // Opticheskii Zhurnal. 2021. V. 88. № 1. P. 53–59. http://doi.org/10.17586/1023-5086-2021-88-01-53-59

For citation (Journal of Optical Technology):

Qian Ma, Lijun Li, Fengjuan Wei, Jianhong Sun, Fei Yu, Jiahui Huang, Xingchen Gu, and Yanhua Ma, "High sensitivity sensors based on open cavity in-fiber Fabry–Perot and Mach–Zehnder interferometers," Journal of Optical Technology. 88(1), 37-41 (2021). https://doi.org/10.1364/JOT.88.000037

Abstract:

Two open cavity in-fiber Fabry–Perot and Mach–Zehnder interferometers are fabricated and their liquid refractive index and temperature sensing characteristics are comparative studied, respectively. In our experiments, for Fabry–Perot interferometric sensor, its dip wavelength versus refractive index and temperature sensitivity is 50.001 nm/RIU (refractive index unit) from 1.3351 to 1.3737 refractive index range and 0.016 nm/deg respectively. For Mach–Zehnder with Fabry–Perot cavity sensor, its dip wavelength versus refractive index and temperature sensitivity is 587.089 nm/RIU at 1.3331–1.3415 refractive index range, –647.755 nm/RIU at 1.3415–1.3737 refractive index range, and 0.032 nm/deg respectively.

Keywords:

interferometer, liquid refractive index, temperature sensor

OCIS codes: 230.2285, 220.4000, 230.3390

References:

1. Li L.J., Ma Q., Cao M.Y., Zhang G.N., Zhang Y., Jiang L., Gao C.T., Yao J., Gong S.S., Li W.X. High stability Michelson refractometer based on an in-fiber interferometer followed with a Faraday rotator mirror // Sens. Actuator B-Chem. 2016. V. 234. P. 674–679.
2. Li L.J., Ma Q., Cao M.Y., Zhang G.N., Zhang Y., Jiang L., Gao C.T., Yao J., Gong S., Li W.X. Study of interference wavelength characteristics of fiber Bragg grating modulated all-fiber inline Mach–Zehnder interferometer // Sensors & Materials. 2017. V. 29. № 1. P. 15–21.
3. Li X.G., Zhao Y., Cai L., Wang Q. Simultaneous measurement of RI and temperature with a FP and Mach–Zehnder composite interferometer // IEEE Photonics Technol. Lett. 2016. V. 28. № 17. P. 1–1.
4. Zhao L., Zhang Y.D., Chen Y.H., Wang G.F. Composite cavity fiber tip Fabry–Perot interferometer for high temperature sensing // Opt. Fiber Technol. 2019. V. 50. № 2019. P. 31–35.
5. Duan D.W., Rao Y.G., Xu L.C., ZhuT., Deng M., Wu D., Yao J. In-fiber Fabry–Perot and Mach–Zehnder interferometers based on hollow optical fiber fabricated by arc fusion splicing with small lateral offsets // Opt. Commun. 2011. V. 284. № 22. P. 5311–5314.
6. Rong Q.Z., Sun H., Qiao X.G., Zhang J., Hu M.L., Fen Z.Y. A miniature fiber-optic temperature sensor based on a Fabry–Perot interferometer // J. Opt. 2012. V. 14. № 4. P. 059501–059501.
7. Xu L.C., Deng M., Duan D.W., Wen W.P., Han M. High-temperature measurement by using a PCF-based Fabry–Perot interferometer // Optics & Lasers in Engineering. 2012. V. 50. № 10. P. 1391–1396.

8. Zhang Y.N., Huang J., Lan X.W., Yuan L., Xiao H. Simultaneous measurement of temperature and pressure with cascaded extrinsic Fabry–Perot interferometer and intrinsic Fabry–Perot interferometer sensors // Opt. Eng. 2014. V. 53. № 6. P. 067101.
9. Jia P.G., Fang G.H., Liang T., Hong Y.P., Tan Q.L., Chen X.Y., Liu W.Y., Xue C.Y., Liu J., Zhang W.D., Xiong J.J. Temperature-compensated fiber-optic Fabry–Perot interferometric gas refractive-index sensor based on hollow silica tube for high-temperature application // Sens. Actuator B-Chem. 2017. V. 244. P. 226–232.
10. Shangguan C.M., Zhang W., Hei W., Luo F., Zhu L.Q. Fabry–Perot cavity cascaded sagnac loops for temperature and strain measurements // Opt. Eng. 2018. V. 57. № 4. P. 1.
11. Ying Y.B., Zhao C.L., Gong H.P., Shang S.Y., Hou L.Y. Demodulation method of Fabry–Perot sensor by cascading a traditional Mach–Zehnder interferometer // Hangzhou: Opt. Laser Technol. 2019. № 118. P. 1391–1396.
12. Wang L.Q., Yang L., Zhang C., Miao C.Y., Zhao J.F., Xu W. High sensitivity and low loss open-cavity Mach–Zehnder interferometer based on multimode interference coupling for refractive index measurement // Opt. Laser Technol. 2019. № 109. P. 193–198.
13. Zhang H., Gao S.H., Luo Y.H., Chen Z.S., Xiong S.S., Wan L., Huang X.C., Huang B.S., Feng Y.H., He M., Liu W.P., Chen Z., Li Z.H. Ultrasensitive Mach–Zehnder interferometric temperature sensor based on liquidfilled D-shaped fiber cavity // Sensors. 2018. V. 18. № 4. P. 1239.