ITMO
ru/ ru

ISSN: 1023-5086

ru/

ISSN: 1023-5086

Scientific and technical

Opticheskii Zhurnal

A full-text English translation of the journal is published by Optica Publishing Group under the title “Journal of Optical Technology”

Article submission Подать статью
Больше информации Back

УДК: 535.243, 615.471, 681.7

The accuracy, reliability, and interpretation of the results of in vivo laser fluorescence diagnosis in the spectral range of the fluorescence of endogenous porphyrins

For Russian citation (Opticheskii Zhurnal):

Рогаткин Д.А., Быченков О.А., Лапаева Л.Г. Точность, достоверность и интерпретация результатов in vivo лазерной флюоресцентной диагностики в спектральном диапазоне флюоресценции эндогенных порфиринов // Оптический журнал. 2009. Т. 76. № 11. С. 46–53.

 

Rogatkin D.A., Bychenkov O.A., Lapaeva L.G. The accuracy, reliability, and interpretation of the results of in vivo laser fluorescence diagnosis in the spectral range of the fluorescence of endogenous porphyrins [in Russian] // Opticheskii Zhurnal. 2009. V. 76. № 11. P. 46–53.

For citation (Journal of Optical Technology):

D. A. Rogatkin, O. A. Bychenkov, and L. G. Lapaeva, "The accuracy, reliability, and interpretation of the results of in vivo laser fluorescence diagnosis in the spectral range of the fluorescence of endogenous porphyrins," Journal of Optical Technology. 76 (11), 708-713 (2009). https://doi.org/10.1364/JOT.76.000708

Abstract:

Based on an analysis of various clinical data, the assumption was recently expressed that the often observed in vivo increased fluorescence of endogenous porphyrins in living biological tissues is a consequence of the status of chronic hypoxia in the tissues. Starting from this, this article discusses the accuracy, reproducibility, and information content of methods of in vivo laser fluorescence diagnosis (LFD) in actual clinical practice. It is shown that, despite the random error of single measurements in LFD of 30-40% established earlier, the accuracy and reliability can reach a fairly high level when the results of the diagnosis are interpreted. The formal random scatter in the results of single measurements is largely determined not by the instrumental error but by the methodological error and by the living and changeable character of the object of diagnosis, especially at the level of the blood-microcirculation system.

Keywords:

-

Acknowledgements:

The research was supported by RFBR, grant No. 08-02-00769.

OCIS codes: 170.6510

References:
-